Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
2.
Circ Arrhythm Electrophysiol ; 17(4): e012374, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38426305

RESUMO

BACKGROUND: A pathogenic/likely pathogenic variant can be found in 20% to 25% of patients with Brugada syndrome (BrS) and a pathogenic/likely pathogenic variant in SCN5A is associated with a worse prognosis. The aim of this study is to define the diagnostic yield of a large gene panel with American College of Medical Genetics and Genomics variant classification and to assess prognosis of SCN5A and non-SCN5A variants. METHODS: All patients with BrS, were prospectively enrolled in the Universitair Ziekenhuis Brussel registry between 1992 and 2022. Inclusion criteria for the study were (1) BrS diagnosis; (2) genetic analysis performed with a large gene panel; (3) classification of variants following American College of Medical Genetics and Genomics guidelines. Patients with a pathogenic/likely pathogenic variant in SCN5A were defined as SCN5A+. Patients with a reported variant in a non-SCN5A gene or with no reported variants were defined as patients with SCN5A-. All variants were classified as missense or predicted loss of function. RESULTS: A total of 500 BrS patients were analyzed. A total of 104 patients (20.8%) were SCN5A+ and 396 patients (79.2%) were SCN5A-. A non-SCN5A gene variant was found in 75 patients (15.0%), of whom, 58 patients (77.3%) had a missense variant and 17 patients (22.7%) had a predicted loss of function variant. At a follow-up of 84.0 months, 48 patients (9.6%) experienced a ventricular arrhythmia (VA). Patients without any variant had higher VA-free survival, compared with carriers of a predicted loss of function variant in SCN5A+ or non-SCN5A genes. There was no difference in VA-free survival between patients without any variant and missense variant carriers in SCN5A+ or non-SCN5A genes. At Cox analysis, SCN5A+ or non-SCN5A predicted loss of function variant was an independent predictor of VA. CONCLUSIONS: In a large BrS cohort, the yield for SCN5A+ is 20.8%. A predicted loss of function variant carrier is an independent predictor of VA.


Assuntos
Síndrome de Brugada , Humanos , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/genética , Testes Genéticos , Arritmias Cardíacas/genética , Mutação de Sentido Incorreto , Canal de Sódio Disparado por Voltagem NAV1.5/genética , Mutação
3.
Heart Rhythm O2 ; 5(2): 137-144, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38545325

RESUMO

Background: Pericarditis is the most common complication following hybrid sinus node-sparing ablation for inappropriate sinus tachycardia (IST)/postural orthostatic tachycardia syndrome (POTS). Objective: The study sought to evaluate the association of prophylaxis therapy on the risk of symptomatic pericarditis following hybrid IST/POTS ablation. Methods: All consecutive patients undergoing to hybrid ablation of symptomatic IST/POTS refractory or intolerant to drugs were retrospectively analyzed. Pharmacological prophylaxis therapy was based on acetylsalicylic acid and colchicine started on the day of the ablation and continued for at least 3 months. The primary endpoint was occurrence of symptomatic pericarditis. The secondary endpoint was occurrence of pericarditis-related complications, including the following: duration of pericarditis >3 months, hospitalization for pericarditis, postpericardiectomy pleuro-pericarditis, and pericardiectomy. Results: A total of 220 patients undergone to hybrid IST/POTS ablation were included and 44 (20%) underwent prophylaxis therapy. Pericarditis occurred in 101 (45.9%) patients, with 97 (96%) in the first 5 days. At survival analysis, prophylaxis was associated with higher rate of freedom from pericarditis (81.9% vs 47.2%, log-rank P < .001). Pericarditis-related complications were low, occurring in 7 (3.2%) patients. There was no difference in pericarditis-related complications between the patients who underwent prophylaxis therapy and patients who did not. At Cox multivariate analysis, predictors of pericarditis were IST (vs POTS) (hazard ratio 0.61, 95% confidence interval0.39-0.99, P = .04) and prophylaxis therapy (hazard ratio 0.27, 95% confidence interval 0.13-0.55, P < .001). Conclusion: In a large cohort of patients undergoing hybrid ablation for IST/POTS, a prophylaxis therapy with acetylsalicylic acid and colchicine was associated with a lower rate of symptomatic pericarditis.

4.
Eur Heart J ; 45(14): 1255-1265, 2024 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-38445836

RESUMO

BACKGROUND AND AIMS: Available data on continuous rhythm monitoring by implantable loop recorders (ILRs) in patients with Brugada syndrome (BrS) are scarce. The aim of this multi-centre study was to evaluate the diagnostic yield and clinical implication of a continuous rhythm monitoring strategy by ILRs in a large cohort of BrS patients and to assess the precise arrhythmic cause of syncopal episodes. METHODS: A total of 370 patients with BrS and ILRs (mean age 43.5 ± 15.9, 33.8% female, 74.1% symptomatic) from 18 international centers were included. Patients were followed with continuous rhythm monitoring for a median follow-up of 3 years. RESULTS: During follow-up, an arrhythmic event was recorded in 30.7% of symptomatic patients [18.6% atrial arrhythmias (AAs), 10.2% bradyarrhythmias (BAs), and 7.3% ventricular arrhythmias (VAs)]. In patients with recurrent syncope, the aetiology was arrhythmic in 22.4% (59.3% BAs, 25.0% VAs, and 15.6% AAs). The ILR led to drug therapy initiation in 11.4%, ablation procedure in 10.9%, implantation of a pacemaker in 2.5%, and a cardioverter-defibrillator in 8%. At multivariate analysis, the presence of symptoms [hazard ratio (HR) 2.5, P = .001] and age >50 years (HR 1.7, P = .016) were independent predictors of arrhythmic events, while inducibility of ventricular fibrillation at the electrophysiological study (HR 9.0, P < .001) was a predictor of VAs. CONCLUSIONS: ILR detects arrhythmic events in nearly 30% of symptomatic BrS patients, leading to appropriate therapy in 70% of them. The most commonly detected arrhythmias are AAs and BAs, while VAs are detected only in 7% of cases. Symptom status can be used to guide ILR implantation.


Assuntos
Síndrome de Brugada , Desfibriladores Implantáveis , Marca-Passo Artificial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Síndrome de Brugada/complicações , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Eletrocardiografia/métodos , Eletrocardiografia Ambulatorial/métodos , Adulto
5.
Heart Rhythm ; 2024 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-38290688

RESUMO

BACKGROUND: Pulsed field ablation (PFA) is selective for the myocardium. However, vagal responses and reversible effects on ganglionated plexi (GP) are observed during pulmonary vein isolation (PVI). Anterior-right GP ablation has been proven to effectively prevent vagal responses during radiofrequency-based PVI. OBJECTIVE: The purpose of this study was to test the hypothesis that PFA-induced transient anterior-right GP modulation when targeting the right superior pulmonary vein (RSPV) before any other pulmonary veins (PVs) may effectively prevent intraprocedural vagal responses. METHODS: Eighty consecutive paroxysmal atrial fibrillation patients undergoing PVI with PFA were prospectively included. In the first 40 patients, PVI was performed first targeting the left superior pulmonary vein (LSPV-first group). In the last 40 patients, RSPV was targeted first, followed by left PVs and right inferior PV (RSPV-first group). Heart rate (HR) and extracardiac vagal stimulation (ECVS) were evaluated at baseline, during PVI, and postablation to assess GP modulation. RESULTS: Vagal responses occurred in 31 patients (78%) in the LSPV-first group and 5 (13%) in the RSPV-first group (P <.001). Temporary pacing was needed in 14 patients (35%) in the LSPV-first group and 3 (8%) in the RSPV-first group (P = .003). RSPV isolation was associated with similar acute HR increase in the 2 groups (13 ± 11 bpm vs 15 ± 12 bpm; P = .3). No significant residual changes in HR or ECVS response were documented in both groups at the end of the procedure compared to baseline (all P >.05). CONCLUSION: PVI with PFA frequently induced vagal responses when initiated from the LSPV. Nevertheless, an RSPV-first approach promoted transient HR increase and reduced vagal response occurrence.

6.
J Interv Card Electrophysiol ; 67(2): 273-283, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37103590

RESUMO

BACKGROUND: Posterior wall (PW) isolation is an important adjunctive ablation target in patients with non-paroxysmal atrial fibrillation (AF). Traditionally performed with point-by-point radiofrequency (RF) ablation, PW isolation has also been performed with different cryoballoon technologies. We aimed at assessing the feasibility of PW isolation with the novel RF balloon catheter Heliostar™ (Biosense Webster, CA, USA). METHODS: We prospectively enrolled 32 consecutive patients with persistent AF scheduled for first-time ablation with the Heliostar™ device. Procedural data were compared with those from 96 consecutive persistent AF patients undergoing pulmonary vein (PV) plus PW isolation with a cryoballoon device. The ratio RF balloon/cryoballoon was 1:3 for each operator involved in the study, aiming at avoiding any imbalance related to different experience. RESULTS: Single-shot PV isolation was documented in a significantly higher number of cases with the RF balloon technology compared to cryoballoon ablation (89.8% vs. 81.0%; p = 0.02, respectively). PW isolation was achieved with a similar number of balloon applications between the two groups (11 ± 4 with the RF balloon versus 11 ± 2 with the cryoballoon; p = 0.16), but in a significantly shorter time among RF balloon patients (228 ± 72 s versus 1274 ± 277 s with cryoballoon; p < 0.001). Primary safety endpoint occurred in none of the RF balloon patients versus 5 (5.2%) patients in the cryoballoon group (p = 0.33). Primary efficacy endpoint was achieved in all (100%) RF balloon patients versus 93 (96.9%) cryoballoon ones (p = 0.57). Oesophageal endoscopy did not show any signs of thermal lesions in RF balloon patients with luminal temperature rise. CONCLUSIONS: RF balloon-based PW isolation was safe and promoted shorter procedure times compared to similar cryoballoon-based ablation procedures.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Criocirurgia/métodos , Estudos de Viabilidade , Resultado do Tratamento , Ablação por Cateter/métodos , Recidiva , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Cateteres
8.
Europace ; 26(1)2023 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-38155611

RESUMO

AIMS: A novel sinus node (SN) sparing hybrid ablation for inappropriate sinus node tachycardia (IST)/postural orthostatic tachycardia syndrome (POTS) has been demonstrated to be an effective and safe therapeutic option in patients with symptomatic drug-resistant IST/POTS. The aim of this study was to evaluate the long-term rate of redo procedures after hybrid IST ablation and procedural strategy, outcomes and safety of redo procedures. METHODS AND RESULTS: All consecutive patients from 2015 to 2023 were prospectively enrolled in the UZ Brussel monocentric IST/POTS registry. They were analysed if the following inclusion criteria were fulfilled: 1) diagnosis of IST or POTS, 2) symptomatic IST/POTS refractory or intolerant to drugs, and 3) hybrid SN sparing ablation performed. The primary endpoint was redo procedure. The primary safety endpoint was pacemaker (PM) implantation. A total of 220 patients undergone to hybrid IST ablation were included, 185 patients (84.1%) were treated for IST and 61 patients (27.7%) for POTS.After a follow-up of 73.3 ± 16.2 months, 34 patients (15.4%) underwent a redo. A total of 23 patients (67.6%) had a redo for IST recurrence and 11 patients (32.4%) for other arrhythmias. Pacemaker implantation was performed in 21 patients (9.5%). Nine patients (4.1%) had no redo procedure and experienced sick sinus syndrome requiring a PM. Twelve patients (5.4%) received a PM as a shared therapeutic choice combined with SN ablation procedure. CONCLUSION: In a large cohort of patients the long-term free survival from redo procedure after hybrid IST ablation was 84.6% with a low PM implantation rate.


Assuntos
Ablação por Cateter , Taquicardia Sinusal , Humanos , Taquicardia Sinusal/diagnóstico , Taquicardia Sinusal/cirurgia , Taquicardia Sinusal/tratamento farmacológico , Nó Sinoatrial , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Frequência Cardíaca
9.
Artigo em Inglês | MEDLINE | ID: mdl-37756702

RESUMO

OBJECTIVES: Brugada syndrome is a life-threatening disease with an arrhythmogenic substrate located in the epicardium of right ventricle outflow tract. Therefore, the correct region identification is crucial for a successful ablation procedure. Various mapping techniques can be adopted to elaborate this issue, but they were all initially developed for endovascular use. METHODS: In this study, we analysed 21 consecutive hybrid video-assisted thoracoscopic ablation of Brugada syndrome, performed using different mapping systems to identify the ablation target and confirm the elimination of arrhythmogenic substrate; 35 maps have been analysed. RESULTS: Acute success of epicardial right ventricle outflow tract ablation has been achieved in 100% of procedures, no periprocedural complications have been observed; HD Grid catheter showed higher area identification speed and faster fractionated potentials visualization; Rhythmia system has demonstrated the best map density; Carto 3 system showed a significant advantage in patient preparation time, but mapping speed was reduced due to focal catheter use only. CONCLUSIONS: All tested electro anatomical mapping systems can be used for hybrid video-assisted thoracoscopic ablation with same clinical success; however, accuracy and efficacy of mapping systems are heterogenous and highly dependent on proper patient preparation, mapping system and physician skills.

10.
JACC Clin Electrophysiol ; 9(10): 2096-2105, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37565952

RESUMO

BACKGROUND: Patients with Brugada syndrome (BrS) have an increased risk of arrhythmias, including atrial tachyarrhythmias (ATas). OBJECTIVES: The purpose of this study was to assess underlying atrial cardiomyopathy in BrS and the effect of ajmaline (AJM) test on the atrium of BrS patients using electrocardiogram imaging (ECGI). METHODS: All consecutive patients diagnosed with BrS in a monocentric registry were screened and included if they met the following criteria: 1) BrS diagnosed following current recommendations; and 2) ECGI map performed before and after AJM with a standard protocol. Consecutive patients with no structural heart disease or BrS who had undergone ECGI were included as a control group. Genetic analysis for SCN5A was performed in all BrS patients. Total atrial conduction time (TACT) and local atrial conduction time (LACT) were calculated from atrial ECGI. The primary endpoint was ATas during follow-up. RESULTS: Forty-three consecutive BrS patients and 40 control patients were included. Both TACT and LACT were significantly prolonged in BrS patients compared with control patients. Furthermore, TACT and LACT were significantly higher after AJM administration and in BrS patients who were carriers of a pathogenic/likely pathogenic SCN5A variant. After a mean follow-up of 40.9 months, 6 patients experienced a first ATa occurrence (all in the BrS group, 13.9%). TACT was the only independent predictor of ATas with a cutoff of >138.5 ms (sensitivity 0.92 [95% CI: 0.83-0.98], specificity 0.70 [95% CI: 0.59-0.81]). CONCLUSIONS: ECGI-calculated TACT and LACT are significantly prolonged in BrS patients compared with control patients, and in BrS patients after AJM. This may be consistent with a concealed atrial cardiomyopathy in BrS.


Assuntos
Fibrilação Atrial , Síndrome de Brugada , Cardiomiopatias , Humanos , Síndrome de Brugada/diagnóstico por imagem , Síndrome de Brugada/genética , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Eletrocardiografia/métodos , Ajmalina
11.
Heart Rhythm ; 20(10): 1429-1435, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37481220

RESUMO

BACKGROUND: The impact of sex in clinical and procedural outcomes in leadless pacemaker (LPM) patients has not yet been investigated. OBJECTIVE: The purpose of this study was to investigate sex-related differences in patients undergoing LPM implantation. METHODS: Consecutive patients enrolled in the i-LEAPER registry were analyzed. Comparisons between sexes were performed within the overall cohort using an adjusted analysis with 1:1 propensity matching for age and comorbidities. The primary outcome was the comparison of major complication rates. Sex-related differences regarding electrical performance and all-cause mortality during follow-up were deemed secondary outcomes. RESULTS: In the overall population (n = 1179 patients; median age 80 years), 64.3% were men. After propensity matching, 738 patients with no significant baseline differences among groups were identified. During median follow-up of 25 [interquartile range 24-39] months, female sex was not associated with LPM-related major complications (hazard ratio [HR] 2.03; 95% confidence interval [CI] 0.70-5.84; P = .190) or all-cause mortality (HR 0.98; 95% CI 0.40-2.42; P = .960). LPM electrical performance results were comparable between groups, except for a higher pacing impedance in women at implant and during follow-up (24 months: 670 [550-800] Ω vs 616 [530-770] Ω; P = .014) that remained within normal limits. CONCLUSION: In a real-world setting, we found differences in sex-related referral patterns for LPM implantation with an underrepresentation of women, although major complication rate and LPM performance were comparable between sexes. Female patients showed higher impedance values, which had no impact on overall device performance. Electrical parameters remained within normal limits in both groups during the entire follow-up.

12.
Heart Rhythm ; 20(10): 1370-1377, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37414109

RESUMO

BACKGROUND: Omnipolar technology (OT) was recently proposed to generate electroanatomic voltage maps with orientation-independent electrograms. We describe the first cohort of patients undergoing ventricular tachycardia (VT) ablation guided by OT. OBJECTIVE: The purpose of this study was to compare omnipolar and bipolar high-density maps with regard to voltage amplitude, late potential (LP) annotation, and isochronal late activation mapping distribution. METHODS: A total of 24 patients (16 [66%] ischemic cardiomyopathy and 12 [50%] redo cases) underwent VT ablation under OT guidance. Twenty-seven sinus rhythm substrate maps and 10 VT activation maps were analyzed. Omnipolar and bipolar (HD Wave Solution algorithm, Abbott, Abbott Park, IL) voltages were compared. Areas of LPs were correlated with the VT isthmus areas, and late electrogram misannotation was evaluated. Deceleration zones based on isochronal late activation maps were analyzed by 2 blinded operators and compared to the VT isthmuses. RESULTS: OT maps had higher point density (13.8 points/cm2 vs 8.0 points/cm2). Omnipolar points had 7.1% higher voltages than bipolar points within areas of dense scar and border zone. The number of misannotated points was significantly lower for OT maps (6.8% vs 21.9%; P = .01), showing comparable sensitivity (53% vs 59%) but higher specificity (79% vs 63%). The sensitivity and specificity of detection of the VT isthmus in the deceleration zones were, respectively, 75% and 65% for OT and 35% and 55% for bipolar mapping. At 8.4 months, 71% freedom from VT recurrence was achieved. CONCLUSION: OT is a valuable tool for guiding VT ablation, providing more accurate identification of LPs and isochronal crowding due to slightly higher voltages.

13.
J Interv Card Electrophysiol ; 66(9): 2135-2142, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37178190

RESUMO

BACKGROUND: The influence of divergent anesthesia types during ablation of premature ventricular complexes (PVCs) is not known. While previously performed under general anesthesia (GA) at our institution, these procedures were exclusively performed under local anesthesia (LA) ± minimal sedation during the COVID-19 outbreak for logistic reasons. METHODS: One hundred and eight consecutive patients (82 GA versus 26 LA) undergoing PVC ablation at our center were evaluated. Intraprocedural PVC burden (over 3 min) pre-ablation was measured twice: (1) at the start (before GA induction) and (2) before catheter insertion (after GA induction). Upon cessation of ablation and after a waiting period of ≥ 15 min, acute ablation success (AAS) was defined as absence of PVCs until the end of the recording period. RESULTS: Intraprocedural PVC burden was not significantly different between LA versus GA group: (1) 17.8 ± 3% vs 12.7 ± 2%, P = 0.17 and (2) 10.0 ± 3% vs 7.4 ± 1%, P = 0.43, respectively. Activation mapping-based ablation was performed significantly more in the LA vs GA group (77% vs 26% of patients, P < 0.001, respectively). AAS was significantly higher in LA vs GA group: 22/26 (85%) vs 41/82 (50%), respectively, P < 0.01. After multivariable analysis, LA was the only independent predictor for AAS (OR 13, 95% CI 1.57-107.4, P = 0.017). CONCLUSION: Ablation of PVC under LA presented significantly higher AAS rate compared to GA. The procedure under GA might be complicated by PVC inhibition (after catheter insertion/during mapping) and PVC disinhibition post-extubation.


Assuntos
Anestésicos , COVID-19 , Ablação por Cateter , Complexos Ventriculares Prematuros , Humanos , Complexos Ventriculares Prematuros/cirurgia , Ablação por Cateter/métodos , Anestesia Local , Resultado do Tratamento
14.
JACC Clin Electrophysiol ; 9(8 Pt 1): 1296-1306, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37227348

RESUMO

BACKGROUND: Different genes have been associated with idiopathic ventricular fibrillation (IVF); however, there are no studies correlating genotype with phenotype. OBJECTIVES: The aim of this study was to define the genetic background of probands with IVF using large gene panel analysis and to correlate genetics with long-term clinical outcomes. METHODS: All consecutive probands with a diagnosis of IVF were included in a multicenter retrospective study. All patients had: 1) IVF diagnosis throughout the follow-up; and 2) genetic analysis with a broad gene panel. All genetic variants were classified as pathogenic/likely pathogenic (P+), variants of unknown significance (VUS) or no variants (NO-V), following current guidelines of the American College of Medical Genetics and Genomics and the Association for Molecular Pathology. The primary endpoint was occurrence of ventricular arrhythmias (VA). RESULTS: Forty-five consecutive patients were included. A variant was found in 12 patients, 3 P+ and 9 VUS carriers. After a mean follow-up time of 105.0 months, there were no deaths and 16 patients (35.6%) experienced a VA. NO-V patients had higher VA free survival during the follow-up, compared with both VUS (72.7% vs 55.6%, log-rank P < 0.001) and P+ (72.7% vs 0%, log-rank P = 0.013). At Cox analysis, P+ or VUS carrier status was a predictor of VA occurrence. CONCLUSIONS: In probands with IVF, undergoing genetic analysis with a broad panel, the diagnostic yield for P+ is 6.7%. P+ or VUS carrier status is a predictor of VA occurrence.


Assuntos
Testes Genéticos , Fibrilação Ventricular , Humanos , Estudos Retrospectivos , Arritmias Cardíacas/complicações
15.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37246904

RESUMO

AIMS: Hybrid atrial fibrillation (AF) ablation is a promising approach in non-paroxysmal AF. The aim of this study is to assess the long-term outcomes of hybrid ablation in a large cohort of patients after both an initial and as a redo procedure. METHODS AND RESULTS: All consecutive patients undergoing hybrid AF ablation at UZ Brussel from 2010 to 2020 were retrospectively evaluated. Hybrid AF ablation was performed in a one-step procedure: (i) thoracoscopic ablation followed by (ii) endocardial mapping and eventual ablation. All patients received PVI and posterior wall isolation. Additional lesions were performed based on clinical indication and physician judgement. Primary endpoint was freedom from atrial tachyarrhythmias (ATas). A total of 120 consecutive patients were included, 85 patients (70.8%) underwent hybrid AF ablation as first procedure (non-paroxysmal AF 100%), 20 patients (16.7%) as second procedure (non-paroxysmal AF 30%), and 15 patients (12.5%) as third procedure (non-paroxysmal AF 33.3%). After a mean follow-up of 62.3 months ± 20.3, a total of 63 patients (52.5%) experienced ATas recurrence. Complications occurred in 12.5% of patients. There was no difference in ATas between patients undergoing hybrid as first vs. redo procedure (P = 0.53). Left atrial volume index and recurrence during blanking period were independent predictors of ATas recurrence. CONCLUSION: In a large cohort of patients undergoing hybrid AF ablation, the survival from ATas recurrence was 47.5% at ≈5 years follow-up. There was no difference in clinical outcomes between patients undergoing hybrid AF ablation as first procedure or as a redo.


Assuntos
Técnicas de Ablação , Fibrilação Atrial , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Seguimentos , Átrios do Coração , Estudos Retrospectivos , Taquicardia , Resultado do Tratamento
16.
Curr Cardiol Rep ; 25(6): 535-542, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37115434

RESUMO

PURPOSE OF REVIEW: Imaging plays a crucial role in the therapy of ventricular tachycardia (VT). We offer an overview of the different methods and provide information on their use in a clinical setting. RECENT FINDINGS: The use of imaging in VT has progressed recently. Intracardiac echography facilitates catheter navigation and the targeting of moving intracardiac structures. Integration of pre-procedural CT or MRI allows for targeting the VT substrate, with major expected impact on VT ablation efficacy and efficiency. Advances in computational modeling may further enhance the performance of imaging, giving access to pre-operative simulation of VT. These advances in non-invasive diagnosis are increasingly being coupled with non-invasive approaches for therapy delivery. This review highlights the latest research on the use of imaging in VT procedures. Image-based strategies are progressively shifting from using images as an adjunct tool to electrophysiological techniques, to an integration of imaging as a central element of the treatment strategy.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas , Coração , Frequência Cardíaca , Ablação por Cateter/métodos , Resultado do Tratamento
17.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37061847

RESUMO

AIMS: A pathogenic/likely pathogenic (P/LP) variant in SCN5A is found in 20-25% of patients with Brugada syndrome (BrS). However, the diagnostic yield and prognosis of gene panel testing in paediatric BrS is unclear. The aim of this study is to define the diagnostic yield and outcomes of SCN5A gene testing with ACMG variant classification in paediatric BrS patients compared with adults. METHODS AND RESULTS: All consecutive patients diagnosed with BrS, between 1992 and 2022, were prospectively enrolled in the UZ Brussel BrS registry. Inclusion criteria were: (i) BrS diagnosis; (ii) genetic analysis performed with a large gene panel; and (iii) classification of gene variants following ACMG guidelines. Paediatric patients were defined as ≤16 years of age. The primary endpoint was ventricular arrhythmias (VAs). A total of 500 BrS patients were included, with 63 paediatric patients and 437 adult patients. Among children with BrS, 29 patients (46%) had a P/LP variant (P+) in SCN5A and no variants were found in 34 (54%) patients (P-). After a mean follow-up of 125.9 months, 8 children (12.7%) experienced a VA, treated with implanted cardioverter defibrillator shock. At survival analysis, P- paediatric patients had higher VA-free survival during the follow-up, compared with P+ paediatric patients. P+ status was an independent predictor of VA. There was no difference in VA-free survival between paediatric and adult BrS patients for both P- and P+. CONCLUSION: In a large BrS cohort, the diagnostic yield for P/LP variants in the paediatric population is 46%. P+ children with BrS have a worse arrhythmic prognosis.


Assuntos
Síndrome de Brugada , Adulto , Humanos , Criança , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/genética , Síndrome de Brugada/terapia , Testes Genéticos , Arritmias Cardíacas/genética , Cardioversão Elétrica , Prognóstico , Eletrocardiografia/métodos , Canal de Sódio Disparado por Voltagem NAV1.5/genética
19.
Europace ; 25(3): 896-904, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36738245

RESUMO

AIMS: The multielectrode radiofrequency balloon catheter (RFB) has been developed to achieve safe and effective pulmonary vein isolation (PVI) for atrial fibrillation (AF) ablation. This single-centre study aimed to evaluate the midterm clinical outcome and predictors of single-shot PVI with the novel RFB. METHODS AND RESULTS: All consecutive patients with symptomatic paroxysmal or persistent AF undergoing first-time PVI with the RFB were prospectively included. Clinical and procedural parameters were systematically collected. The primary safety endpoint was defined as any major periprocedural complications. The primary efficacy endpoint consisted of freedom from any atrial tachyarrhythmias (ATas) lasting >30 s during the follow-up after a 3-month blanking period. Persistent single-shot PVI was defined as PVI achieved with a single RFB application without acute reconnection. A total of 104 consecutive patients (mean age 64.3 ± 11.4 years, 56.7% males) were included. 15 patients (14.4%) presented with persistent AF. The procedure time was 59.0 min with a dwell time of 20.0 min. One major complication occurred in one patient. At a mean follow-up of 10.1 ± 5.3 months, freedom from ATas was 82.9%. ATas occurred in 14 patients, 11/69 patients (15.9%) with paroxysmal AF and 3/13 (23.1%) with persistent AF. The best cut-offs to predict persistent single-shot PVI were impedance drop >19.2 Ω [area under the receiver operator characteristic curve (AUC) 0.74] and temperature rise >11.1° C (AUC 0.77). CONCLUSION: In a large cohort of patients undergoing PVI with the RFB, the complication rate was 1%. At a mid-term follow-up of 10.1 ± 5.3 months, freedom from ATas was 82.9%. Specific cut-offs of impedance drop and temperature rise may be useful to predict persistent single-shot isolation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Resultado do Tratamento , Seguimentos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Taquicardia/cirurgia , Cateteres , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
20.
J Clin Med ; 12(3)2023 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-36769681

RESUMO

Background: The lack of thermally and mechanically performant biomaterials represents the major limit for 3D-printed surgical guides, aimed at facilitating complex surgery and ablations. Methods: Cryosurgery is a treatment for cardiac arrhythmias. It consists of obtaining cryolesions, by freezing the target tissue, resulting in selective and irreversible damage. MED625FLX and TPU95A are two biocompatible materials for surgical guides; however, there are no data on their response to cryoenergy delivery. The study purpose is to evaluate the biomaterials' thermal properties, examining the temperature changes on the porcine muscle samples (PMS) when the biomaterials are in place during the cryoablation. Two biomaterials were selected, MED625FLX and TPU95A, with two thicknesses (1.0 and 2.5 mm). To analyze the biomaterials' behavior, the PMS temperatures were measured during cryoablation, firstly without biomaterials (control) and after with the biomaterials in place. To verify the biomaterials' suitability, the temperatures under the biomaterial samples should not exceed a limit of -30.0 °C. Furthermore, the biomaterials' geometry after cryoablation was evaluated using the grid paper test. Results: TPU95A (1.0 and 2.5 mm) successfully passed all tests, making this material suitable for cryoablation treatment. MED625FLX of 1.0 mm did not retain its shape, losing its function according to the grid paper test. Further, MED625FLX of 2.5 mm is also suitable for use with a cryoenergy source. Conclusions: TPU95A (1.0 and 2.5 mm) and MED625FLX of 2.5 mm could be used in the design of surgical guides for cryoablation treatment, because of their mechanical, geometrical, and thermal properties. The positive results from the thermal tests on these materials and their thickness prompt further clinical investigation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...